Delivering an ultrasensitive biomarker measurement that you can count on.
The Center for Memory & Aging Analyzer Core is located on North Campus at the Neurobiology Research Facility in Domenici Hall. Our laboratory offers three advanced analytical platforms for investigators to utilize. These platforms include the Quanterix SIMOA ® HD-X, MESO ® QuickPlex SQ 120MM, and BioTek Synergy H1. We offer full and partial services for sample analysis on each of these systems. We also provide full and partial biofluid processing services. Our experienced staff provide specialized laboratory support, including expert knowledge of each system, hundreds of hours of hands-on protocol and assay development, and specialized troubleshooting skills to aid investigators in their research endeavors.
![]() |
The HD-X is the world’s most sensitive, fully automated immunoassay platform with multiplexing and custom assay capabilities. Using a bead-based immunoassay platform, the new flagship HD-X Analyzer delivers major productivity enhancements, greater user flexibility, unparalleled sensitivity, and best-in-class assay performance across a broad assay selection to empower biomarker research and accelerate drug development. For more information regarding the SIMOA HD-X, please visit: quanterix.com/simoa-hd-x-analyzer |
![]() |
MesoScale MESO ® QuickPlex SQ 120MM Analyzer is MSD's most versatile instrument. This compact system has been engineered for reliability and ease of use. The combination of rapid read times and the ability to perform multiple, simultaneous tests on a single sample increases productivity, saves sample, and delivers results quickly. For more information regarding the MESO QuickPlex SQ 120MM, please visit: mesoscale products & services. |
![]() |
Flexible modular multimode microplate reader, with monochromator-based optics and filter-based optics for fluorescence and luminescence detection. This system supports top and bottom fluorescence intensity, UV-visible absorbance and high performance luminescence detection. For more information regarding the BioTek Synergy H1, please visit: agilent.com |
![]() |
Allegra X-14 centrifuge is intended for the separation of components through the use of relative centrifugal force. It is designed to separate human samples, including blood and other body fluids, for processing, and analysis, as well as nonhuman body samples and chemicals. Max speed of 4,300 RPM and max RCF of 4,303 x g. Run temp can be set between 2 and 40 C. |
All users must submit a signed MOU for each project and choose an option.
Download CMA Analyzer Core Price Sheet
Option A: Full Service
For investigators who need access to the specified equipment, and have staff who are not trained in the particular techniques required to perform the assays and/or fluid processing, or would prefer the CMA Analyzer Core’s expert staff to perform the assay testing and/or fluid processing.
The investigator will provide the following.
For Assays:
For Fluid Processing:
Bench consumables are included in the full service costs. Assay data will be returned to the investigator once completed. Fully processed biofluids will be returned to the investigator after an agreed upon time period.
Option B: Partial Service
For investigators who already have experienced staff that can perform the assays or fluid processing within their study, but the equipment is not available in the investigator’s facilities. The investigator will provide all reagents, kits, and consumables (including bench consumables) for their staff to utilize. The CMA Analyzer Core will provide the use of the equipment under the supervision of the core, any SOPs, calibrations, maintenance, trouble shooting, and guidance on the setting-up and shut-down of equipment.
An already prepped / read ready plate is handed to our research staff, along with a plate layout, and any needed supplies. Items are inserted into the HD-X, MESO QuickPlex, or BioTek, and the data is returned to you.
For biofluid processing, partial service includes only the use of the core’s centrifuge to spin sample., Once your sample is spun down utilizing your preferred SOP, it will be handed back to the investigator for their staff to process. Utilization of our lab space to process your sample can be arranged.
Kiran Bhaskar, PhD
Co-Director, UNM New Mexico Alzheimer's Disease Research Center
Professor, UNM Molecular Genetics and Microbiology
Phone: (505) 272-1230
Email: kbhaskar@salud.unm.edu
Gary Rosenberg, MD
Professor, UNM Neurology,
Founding Director, UNM Center for Memory and Aging
Director, UNM New Mexico Alzheimer's Disease Research Center
Phone: 505-277-3215
Email: GRosenberg@salud.unm.edu
Sasha Hobson
Senior Research Specialist
UNM Center for Memory & Aging
Phone: (505) 272-8010
Email: sahobson@health.unm.edu
Physical Address:
Pete and Nancy Domenici Hall
Room Numbers: 1311
1101 Yale Blvd NE
Albuquerque, NM 87106-0001, USA
Mailing Address:
Attn: Dr. Kiran Bhaskar
Domenici Hall
MSC08 4660
1 University of New Mexico
Albuquerque, NM 87131-0001, USA
Shipping Address:
Attn: Sasha Hobson
University of New Mexico
915 Camino de Salud NE
Domenici Hall 260 R1311
Albuquerque, NM 87131, USA
Publications containing assay results, data, images or products generated by the core require citation in the acknowledgment section of the paper to include the core name, core personnel and any grants that directly support core operations. Core specific information is below:
Sample Acknowledgement Statement:
This research was supported by UNM Center for Memory & Aging, NM Alzheimer’s Disease Research Center & UNM Center for Memory & Aging Analyzer Core, Grant No.NIH P30AG086404.
![]() |
The HD-X is the world’s most sensitive, fully automated immunoassay platform with multiplexing and custom assay capabilities. Using a bead-based immunoassay platform, the new flagship HD-X Analyzer delivers major productivity enhancements, greater user flexibility, unparalleled sensitivity, and best-in-class assay performance across a broad assay selection to empower biomarker research and accelerate drug development. For more information regarding the SIMOA HD-X, please visit: quanterix.com/simoa-hd-x-analyzer |
![]() |
MesoScale MESO ® QuickPlex SQ 120MM Analyzer is MSD's most versatile instrument. This compact system has been engineered for reliability and ease of use. The combination of rapid read times and the ability to perform multiple, simultaneous tests on a single sample increases productivity, saves sample, and delivers results quickly. For more information regarding the MESO QuickPlex SQ 120MM, please visit: mesoscale products & services. |
![]() |
Flexible modular multimode microplate reader, with monochromator-based optics and filter-based optics for fluorescence and luminescence detection. This system supports top and bottom fluorescence intensity, UV-visible absorbance and high performance luminescence detection. For more information regarding the BioTek Synergy H1, please visit: agilent.com |
![]() |
Allegra X-14 centrifuge is intended for the separation of components through the use of relative centrifugal force. It is designed to separate human samples, including blood and other body fluids, for processing, and analysis, as well as nonhuman body samples and chemicals. Max speed of 4,300 RPM and max RCF of 4,303 x g. Run temp can be set between 2 and 40 C. |
All users must submit a signed MOU for each project and choose an option.
Download CMA Analyzer Core Price Sheet
Option A: Full Service
For investigators who need access to the specified equipment, and have staff who are not trained in the particular techniques required to perform the assays and/or fluid processing, or would prefer the CMA Analyzer Core’s expert staff to perform the assay testing and/or fluid processing.
The investigator will provide the following.
For Assays:
For Fluid Processing:
Bench consumables are included in the full service costs. Assay data will be returned to the investigator once completed. Fully processed biofluids will be returned to the investigator after an agreed upon time period.
Option B: Partial Service
For investigators who already have experienced staff that can perform the assays or fluid processing within their study, but the equipment is not available in the investigator’s facilities. The investigator will provide all reagents, kits, and consumables (including bench consumables) for their staff to utilize. The CMA Analyzer Core will provide the use of the equipment under the supervision of the core, any SOPs, calibrations, maintenance, trouble shooting, and guidance on the setting-up and shut-down of equipment.
An already prepped / read ready plate is handed to our research staff, along with a plate layout, and any needed supplies. Items are inserted into the HD-X, MESO QuickPlex, or BioTek, and the data is returned to you.
For biofluid processing, partial service includes only the use of the core’s centrifuge to spin sample., Once your sample is spun down utilizing your preferred SOP, it will be handed back to the investigator for their staff to process. Utilization of our lab space to process your sample can be arranged.
Kiran Bhaskar, PhD
Co-Director, UNM New Mexico Alzheimer's Disease Research Center
Professor, UNM Molecular Genetics and Microbiology
Phone: (505) 272-1230
Email: kbhaskar@salud.unm.edu
Gary Rosenberg, MD
Professor, UNM Neurology,
Founding Director, UNM Center for Memory and Aging
Director, UNM New Mexico Alzheimer's Disease Research Center
Phone: 505-277-3215
Email: GRosenberg@salud.unm.edu
Sasha Hobson
Senior Research Specialist
UNM Center for Memory & Aging
Phone: (505) 272-8010
Email: sahobson@health.unm.edu
Physical Address:
Pete and Nancy Domenici Hall
Room Numbers: 1311
1101 Yale Blvd NE
Albuquerque, NM 87106-0001, USA
Mailing Address:
Attn: Dr. Kiran Bhaskar
Domenici Hall
MSC08 4660
1 University of New Mexico
Albuquerque, NM 87131-0001, USA
Shipping Address:
Attn: Sasha Hobson
University of New Mexico
915 Camino de Salud NE
Domenici Hall 260 R1311
Albuquerque, NM 87131, USA
Publications containing assay results, data, images or products generated by the core require citation in the acknowledgment section of the paper to include the core name, core personnel and any grants that directly support core operations. Core specific information is below:
Sample Acknowledgement Statement:
This research was supported by UNM Center for Memory & Aging, NM Alzheimer’s Disease Research Center & UNM Center for Memory & Aging Analyzer Core, Grant No.NIH P30AG086404.
|
Item:
|
Rate:
|
|
Option A:
Full Service Fee |
UNM: $350 per kit run
Non-UNM: $550 per kit run |
|
Option B:
Partial Service Fee |
UNM: $175 per kit run
Non-UNM: $275 per kit run |
ADDITIONAL NOTES:
Pricing for assay kits, disc pack, and buffer sets from Quanterix are not included. Prices are dependent on which kits the investigator is interested in running. Each disc kit and buffer set are good to run 4 kits.
Please visit Quanterix's website for details: quanterix.com/simoa-assay-kits/
One Quanterix kit will allow for 96 tests in total. Each kit has standards and controls, the number of each is dependent on the kit. For a standard kit, there are 8 standards and 2 controls provided. It is recommended to run the standards, controls, and samples, at minimum, in duplicate. The standards and controls will account for 20 tests, and the samples will account for 76 tests.
Please refer to the protocol to identify the number of standards and controls that are required on your selected kit at portal.quanterix.com
To run everything in duplicate: (8 Standards X 2) + (2 Controls X 2) + (38 Samples X 2) = 96 Tests
If you are running less than 38 samples (not the entire plate) or do not plan to purchase supplies (disk pack and buffer sets) will require an additional service fee:
UNM: $20/sample + $350/kit
Non-UNM: $25/sample + $550/kit
|
Item:
|
Rate:
|
|
Option A:
Full Service Fee |
UNM: $350 per kit run
Non-UNM: $550 per kit run |
|
Option B:
Partial Service Fee |
UNM: $50 per plate read
Non-UNM: $75 per plate read |
ADDITIONAL NOTES:
Pricing for kits from MSD is not included. Prices are dependent on which kits the investigator is interested in running. Please visit their website for details: https://www.mesoscale.com/en/products_and_services/assay_kits
Please ensure the kit chosen is compatible with the MESO QuickPlex SQ 120MM
One MSD kit will allow for 96 tests in total. For a standard kit, there are 8 standards provided. It is recommended to run the standards, samples, at minimum, in duplicate. The standards will account for 16 tests, and the samples will account for 80 tests.
To run everything in duplicate: (8 Standards X 2) + (40 Samples X 2) = 96 Tests
|
Item:
|
Rate:
|
|
Option A:
Full Service Fee |
UNM: $350 per kit run
Non-UNM: $550 per kit run |
|
Option B:
Partial Service Fee |
UNM: $50 per plate read
Non-UNM: $75 per plate read |
ADDITIONAL NOTES:
Pricing for kits is not included in the service fee. Prices are dependent on which kits the investigator is interested in running. Please visit your preferred ELISA distributor’s website for details.
Please ensure the kit chosen is compatible with the BioTek Synergy H1.
|
Item:
|
Rate:
|
|
Option A:
Full Service Fee |
UNM: $50.00 / full processing Non-UNM: $55.00 / full processing |
|
Option B:
Partial Service Fee |
UNM: $15.00 / spin Non-UNM: $20.00 / spin |
Note: Full processing includes spinning, aliquoting, labeling, and freezing/temporary storage.
|
Item:
|
Rate:
|
| Institutional Review Board (IRB) Approval | $1,500 |
| Material Transfer Agreement (MTA) | $500 |
Note: These charges will be added if your institution requires UNM to submit IRB approval and/or a MTA.
Principle Investigators
Kiran Bhaskar, PhD
Gary Rosenberg, MD